Then connect the two using 22 AWG stranded and shielded cable. If your Output Module is located more than 18 inches from the keypad (up to a maximum of 100 feet), you must cut the wire harness in half and plug one half into the keypad the other into the Output Module. IEIs Door-Gard Series SSWiLM keypad combines elegant looks with a mullion mount design in a rugged, vandal resistant case, which you can use for almost any application. Wiring the 2000-8EX Output Module If the Output Module is within 18 inches of the keypad, use the 6conductor wire harness, supplied with the Output Module, to make the connection. The 232iLM Access Control unit consists of two pieces: an SSWiLM keypad front end and a 232 Access Control Module. Programming Keypad Parameters (Default settings are in bold) Command/Action Change Keypad Parameters Keys to Enter/Details 32 # parameter # value # ** Parameter Value 0 – Duress Output Duration 1 – 255 Seconds (default = 5) 1 – Panic Output Duration* 1 – 255 Seconds (default = 5) 2 – Error Lockout Threshold 1 – 50 Attempts (default = 3) 3 – Error Lockout Duration 1 – 255 Seconds (default = 10) 4 – Auto-Entry Count 2 – 10 Digits (default = 4) 7 – Auto-Entry Keypress 2 – 15 Seconds (default = 2) Timeout 10